Automatic screw driving & non-standard automation equipment — Manufacturer since 2011
CB CBZINChengbo Intelligent Technology
Home/Solutions/Medical devices
Industry solution

Screw driving for medical device assembly

Medical device assembly is bought on documentation as much as on tolerance. The machine is part of the quality system, not a faster pair of hands.

At a glanceTypical fastening: M1.7 – M3.0 · single- and dual-platform screw driving and dispensing cells configured per part · built in Dongguan, China since 2011

Most engineers arriving here go straight to one of these:

Industry solution

Diagnostic instruments, monitors, pumps and reusable surgical hardware are assembled with small screws — often M1.7 to M3.0 — into metal inserts or plastic housings. Torque specifications come from the design record and are not negotiable on the line, and the assembly process itself has to be documented and repeatable for regulatory reasons.

The practical consequence is that the machine has to produce evidence. Per-unit tightening data, program version control and a record of which program ran on which unit turn a screw-driving station into a process step that can be validated. That is a different requirement from the automotive case only in emphasis: here it is the process that is being documented, not the customer's acceptance.

Assembly conditions also matter more often. Some device assemblies are built in controlled environments, and some components are static-sensitive or have short handling windows after cleaning. A contained screw path and freedom from loose fasteners on the bench are usually asked for, and we build the station that way.

What to specify

What decides the machine for this application

These are the parameters we need from you to configure a station rather than to guess at one.

Specified torque and tolerance

Take the values from the design record rather than from a trial; the machine is programmed to the specification and monitored against it.

Record retention

Decide how long per-unit tightening data must be retained and in what form; this drives whether the machine logs locally or publishes to a system.

Program control

If the process is validated, program changes need to be controlled and traceable. Agree the change procedure before commissioning.

Cleanliness and handling

Contained screw feed, no loose fasteners on the deck, and tooling compatible with the environment the station sits in.

Small-screw feed

At M1.7 and below, vacuum pick-up is usually more reliable than a mechanical feeder.

Common questions

Frequently asked questions

Can the machine be used in a validated process?
It records per-unit tightening data and runs version-controlled programs, which is what validation normally requires from the station. Formal validation documentation is your quality system's output — we supply the machine data it needs.
How is an M1.7 screw presented reliably?
Vacuum pick-up. At that size the head geometry is easier to present than to singulate, and avoiding a mechanical feeder removes the main stoppage source.
Does the machine support controlled environment assembly?
The screw path is contained and there are no loose fasteners on the working deck. Tell us the environment class and any material restrictions and we will match the machine to it.
Keep reading

Related pages

Tell us about your joint

Send the part, the screw size and the torque window and we will come back with a configuration and a cycle-time estimate.