The interface is a small amount of work if it is specified before the machine is built, and a project if it is specified afterwards.
At a glanceFields per screw Target torque, achieved torque, angle, pass/fail, timestamp, program identity and screw position. · Unit identity Scanned at a standalone machine, or taken automatically from line control where the station is in line.
Most engineers arriving here go straight to one of these:
A screw-driving station that reports to an MES is doing two things: it drives the screws, and it produces a stream of measurements. The measurements are per screw — target torque, achieved torque, angle, result, timestamp — and they need three pieces of context to be useful: which unit they belong to, which program was running, and which position on the unit the screw occupies.
The unit identity is the part of the interface that customers most often leave unspecified. If the machine is standalone, the operator scans or enters a serial number and the record is grouped under it. If the machine is in line, the identity should come from the line control system automatically, because asking a human to type a serial number at machine speed is how records end up attached to the wrong unit. Agree which of the two applies before configuration.
On the machine side, our platforms publish over Ethernet or Wi-Fi and hold the records as tamper-proof entries, so the same data can serve both the plant's quality system and the customer's acceptance requirement without a second measurement. Practically, the specification exercise is short and worth doing early: list the fields your MES needs, say how the unit identity arrives, and confirm whether the machine must also be able to reject a unit and signal the line to divert it.
Last updated 2026-11-20. Screw range, torque and cycle-time figures reflect the current published platform specifications.
The practical conclusions from the sections above.
Target torque, achieved torque, angle, pass/fail, timestamp, program identity and screw position.
Scanned at a standalone machine, or taken automatically from line control where the station is in line.
Ethernet or Wi-Fi from the machine; agree the protocol with your MES team early.
Records captured at the driver with no editing path, so they can be used as acceptance evidence.
Decide whether a failed unit must trigger a line diverter or simply raise an alarm at the station.
Agree what happens when the network is down — buffering on the machine is usually the requirement.
Describe the part and the joint and we will tell you which configuration fits — or whether you do not need a machine at all.