Automatic screw driving & non-standard automation equipment — Manufacturer since 2011
CB CBZINChengbo Intelligent Technology
Home/Guides/Screw driving defect triage
Technical guide

Screw driving defects: triage before you adjust anything

Four faults cover almost every complaint about an automated screw driver. Each one has a different first check, and in three of the four the torque setting is not the cause.

At a glanceStripped thread Bit engagement and hole thread first. Reducing torque turns a visible defect into an invisible one. · Floating screw Screw length against stack height, and hole depth. Torque arrives early, angle stays small.

Most engineers arriving here go straight to one of these:

Technical guide

Name the fault precisely before touching the machine, because these four get confused constantly. A stripped thread keeps rotating after the screw should have seated. A floating screw reaches target torque while the parts are still apart. A cross-thread starts crooked and never seats. A missing screw was never driven at all. The torque and angle record separates them in seconds — if you read angle as well as torque.

Stripped thread: the first check is bit engagement, not the torque setting. If the bit only reaches part of the recess depth, or the recess is worn, the driver cam-outs and removes material instead of turning the screw. The second check is the hole — a punched or rolled hole in thin sheet has very little thread to begin with. Lowering the torque stops the visible damage and leaves the joint under-clamped, which is worse, because nothing about the part looks wrong.

Floating screw is usually geometry rather than force: a screw too long for the stack, a hole that bottoms out, or a thread-forming screw run into a boss that has already been formed once. The driver reaches target torque on the friction of a bottomed screw instead of clamp load, and the angle is tiny. Missing screw is a sequence or confirmation fault — the program skipped a position, or a sensor reported a screw that was not there. The driver is the wrong place to look for that one.

Last updated 2026-11-20. Screw range, torque and cycle-time figures reflect the current published platform specifications.

What to specify

Key points to take away

The practical conclusions from the sections above.

Stripped thread

Bit engagement and hole thread first. Reducing torque turns a visible defect into an invisible one.

Floating screw

Screw length against stack height, and hole depth. Torque arrives early, angle stays small.

Cross-thread

Presentation and chamfer. If the screw starts before the driver descends, no setting fixes it.

Missing screw

Sequence and feed confirmation, not the driver. One screw can satisfy two sensors.

Angle, not torque

Too many degrees means the thread gave way; too few means the joint bottomed before it closed.

Common questions

Frequently asked questions

How can I tell a stripped thread from a screw that never seated?
Look at the tightening angle. A stripped thread keeps turning well past the angle a good joint needs, with torque never building. A screw that bottoms out or cross-threads reaches target torque in very few degrees. The torque value alone can be identical in both cases, which is why it misleads.
Is lowering the torque a valid fix for stripped threads?
No. It removes the symptom by stopping the driver before the thread fails, and leaves a joint that is not clamped to specification. Fix the engagement, the hole or the screw, and keep the torque where the joint needs it.
Do I need a torque transducer to see this?
No, but you need angle as well as torque. A driver that reports only a torque value hides the difference between the two faults. Most servo drivers already log both.
Keep reading

Related pages

Not sure which applies to you?

Describe the part and the joint and we will tell you which configuration fits — or whether you do not need a machine at all.